[Rivet] [Rivet-svn] r2095 - in trunk: data/plotinfo?src/AnalysesDavid Grellscheid david.grellscheid at durham.ac.ukThu Nov 26 10:08:00 GMT 2009
Hi, I wasn't yet subscribed, so sorry if I'm rehashing an old point that you've already gone over: > Right, which is why the post-processing scripts need to be clearly > identified as part of the standard process If you really want to enforce this, why not save the generator histos as raw (weighted) counts, including (in the same file) the total N and the generator cross-section. Then it's very clear right away that post-processing is needed for whatever desired outcome. Pre-selecting one of the possible normalization choices (1) will never lead to agreement on what the "natural" presentation form is. David (1) On top of that, making a different choice for each analysis is even more confusing.